With the continuous upgrading of global building fire safety codes and green construction standards, construction cables require higher standards in flame retardancy, insulation stability, processing ...
READ MORECompliant with building fire safety regulations, widely used for various types of building cables in residential, commercial complexes, and hospitals. Meets environmental requirements such as GB/T 32129-2015, ROSH2.0, REACH, etc.
| No. | Project | Unit | Standard | Typical values | ||||
| DS-WDZH-01A(JZ) | DS-WDZH-01B(JZ) | DS-WDZH-01(JZ) | DS-WDZH-02(JZ) | |||||
| 1 | Density | g/cm3 | / | 1.48 | 1.48 | 1.48 | 1.49 | |
| 2 | Tensile strength | MPa | ≥10.0 | 13 | 13 | 13 | 12 | |
| 3 | Elongation at break | % | ≥160 | 175 | 175 | 180 | 180 | |
| 4 | Oxygen index | % | ≥30 | 35 | 35 | 34 | 32 | |
| 5 | Air thermal aging 100℃*168h | Change rate of tensile strength | % | ±25 | +9 | +9 | +10 | +12 |
| Elongation rate of change | % | ±25 | -5 | -5 | -5 | -10 | ||
| 6 | Thermal denaturation 90℃*1h | % | ≤50 | 7 | 8 | 10 | 10 | |
| 7 | Thermal shock resistance 130℃ | / | No cracking | No cracking | No cracking | No cracking | No cracking | |
| 8 | Smoke density | Flaming | / | ≤100 | 78 | 75 | 70 | 70 |
| Flameless | / | ≤350 | 310 | 318 | 305 | 320 | ||
| 9 | Volume resistivity at 20℃ | Ω·cm | 1.0×10^12 | 1.6×10^13 | 1.6×10^13 | 1.5×10^13 | 1.5×10^13 | |
| 10 | Ozone resistance test 25℃*24h*300ppm | / | No cracking | No cracking | No cracking | No cracking | No cracking | |
| 11 | Low temperature brittleness temperature | ℃ | -25 | Pass | Pass | Pass | Pass | |
| 12 | pH | / | ≥4.3 | 5.2 | 5.1 | 5.2 | 5.1 | |
| 13 | HCl and HBr content | % | ≤0.5 | <0.5 | <0.5 | <0.5 | <0.5 | |
| 14 | Conductivity | uS/mm | ≤10 | 1.1 | 1.1 | 1.1 | 1.1 | |
With the continuous upgrading of global building fire safety codes and green construction standards, construction cables require higher standards in flame retardancy, insulation stability, processing ...
READ MOREDriven by the global dual-carbon strategy and the rapid expansion of photovoltaic new energy markets, outdoor PV cables face extreme operating conditions such as long-term high-temperature exposure, s...
READ MOREWith the continuous upgrading of national and international building fire safety codes, high-rise buildings, hospitals, rail transit, and underground pipe gallery projects have put forward higher requ...
READ MOREDriven by stricter global construction fire safety codes and green building standards, the demand for low-smoke zero-halogen (LSZH) cable materials has surged in high-rise buildings, hospitals, metro ...
READ MORE